Air Lock Advisory

You’ve made a sound decision in hiring Edenflo to clean your sanitary or storm water pump station. We’ll work to ensure that your pumps, floats and electrical system will run efficiently for years to come.

In order for us to service your system properly we need to wash to the bottom of the pump pit to ensure a thorough and proper clean. When we do this we risk an air lock, which will not allow the pumps to push waste through the system. Most times our Technicians can get rid of the air lock without any issue but when a difficult air lock does occur different steps may need to be taken to get the waste moving, depending on the situation.

  1. We may need to enter the pump station which will require us to obtain confined space equipment from our shop and release the air from between the pump and the check valve using a small drill bit.
  2. Other times we may be required to get assistance in jiggling the pumps slightly to get the flow going.
  3. In a worst case scenario we would call a pump specialist.

In our experience an air lock occurs in approximately 5% of the pump station cleans and this advisory is simply to suggest to you that there may be additional charges if an air lock occurs. Once again, if we don’t clean down to the bottom of the pump station we aren’t doing a thorough job on your equipment.

Please call me with any questions or concerns.

Todd Anderson
Chief of Service & Operations
service@edenflo.ca

Simple Science

What is an Air lock

An air lock is a restriction of, or complete stoppage of liquid flow caused by air trapped in a high point of liquid-filled pipe system. The air, being less dense than the liquid, rises to any high points. When pressure is applied, instead of the liquid flowing as it would if the system was full of liquid, the system behaves like a series of manometers.

Flushing the system with high flow or pressures can help move the gas away from the highest point, or a tap (or automatic vent valve) can be installed to let the gas out. Air lock problems often occur when one is trying to re-commission a system after it has been deliberately (for servicing) or accidentally emptied. An air lock may stop flow through that part of the circuit completely. Note that circulating pumps usually do not generate enough pressure to overcome air locks.